APC Smart-UPS 3000VA RM 2U LCD (120V)
$1,399.99 $
- Intuitive LCD Interface
- Predictive Replace Battery Date
- Green Mode
- Energy Meter
- Outlet Group Control
- Sequenced Shutdown and Restart
- Pure Sine Wave Output on Battery
- Single Switched Outlet Group
- Sine Wave Output
- InfraStruXure Central Compatible
Description
The APC Smart-UPS 3000VA RM 2U LCD (120V) provides a continuous supply of battery power for connected devices in the event of an AC power loss. It also safeguards equipment from surges, spikes, lightning, and electrical disturbances. An on-board LCD display, available in multiple languages, gives you a comprehensive and precise readout on critical system functionality. A unique feature of this UPS is green mode which, by bypassing unused electrical components in good power conditions, saves energy costs while reducing the impact on the environment.
This UPS (Uninterruptible Power Supply) incorporates a notification process which will let you know the month and year that the battery is recommended for replacement so you can plan ahead of time. The system will also notify you if it detects a problem with the battery so you can take the proper measures before it fails completely. Thanks to hot-swap support you can replace the battery on the fly without interrupting the surge protection functionality.
There’s a USB connection that enables configuration and control from a PC. It also has a Smart-Slot for integrating the UPS into a network for remote accessibility. There’s also an Automatic Voltage Regulator (AVR) which ensures clean and uninterrupted AC power by correcting low and high voltage conditions without using the battery.
An intelligent battery management system prolongs battery life by using a charging method that takes into account the battery’s age, capacity, temperature, and other factors. An automatic self-test function periodically checks the efficiency of the battery and provides notification when the battery is nearing the end of its usefulness. If the battery requires replacement it can be done easily without the need for tools. The system will also notify you if the battery is disconnected. An LED indicator lets you see at a glance power and battery status. The UPS also features an automatic restart function which will automatically power up devices after AC is restored.
This UPS is ideal for servers, point-of-sale, routers, switches, hubs and other network devices.
- Intuitive LCD Interface
- Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Predictive Replace Battery Date
- Dynamically provides the month and year when battery replacement is recommended to aid in long term maintenance planning.
- Green Mode
- Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Energy Meter
- Provides actual kilowatt hours of usage for energy conscious users.
- Outlet Group Control
- Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
- Sequenced Shutdown and Restart
- Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).
- InfraStruXure Central Compatible
- Enables centralized management via APC InfraStruXure Central.
- Pure Sine Wave Output on Battery
- Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Single Switched Outlet Group
- Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Sine Wave Output
- Eliminates humming and heat generated when powering tubelights and fans.
- Battery Failure Notification
- Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- LED Indicators
- Provide easy-to-read status of the unit and utility power conditions.
- Hot-Swappable Batteries
- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Disconnected Battery Notification
- Warns when a battery is not available to provide backup power.
- Automatic Self-Test
- Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic Restart of Loads After UPS Shutdown
- Automatically starts up the connected equipment upon the return of utility power.
- Adjustable Voltage Transfer Points
- Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Adjustable Voltage Sensitivity
- Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Audible Alarms
- Provides notification of changing utility power and UPS conditions
- User-Replaceable Batteries
- Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- USB Connectivity
- Provides management of the UPS via a USB port (not available on all models).
- Serial Connectivity
- Provides management of the UPS via a serial port.
- Temperature-Compensated Battery Charging
- Prolongs battery life by regulating the charge voltage according to battery temperature.
- Boost and Trim Automatic Voltage Regulation (AVR)
- Gives higher application availability by correcting low and high voltage conditions without using the battery.
- Intelligent Battery Management
- Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Safety Agency Approved
- Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Network Manageable
- Provides remote management of the UPS over the network.
- Predictive Failure Notification
- Provides early-warning fault analysis ensuring proactive component replacement.
- Power Conditioning
- Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Resettable Circuit Breakers
- Enables a quick recovery from overload events.